Regulatory Compliance

At MDS, we specialize in helping medical device manufacturers and healthcare providers meet stringent regulatory requirements. Our expertise spans international standards such as ISO 17664, ISO 15883, and EN285, ensuring your devices comply with the latest guidelines for cleaning, disinfection, and sterilization. We provide thorough validation services, comprehensive reporting, and tailored training to ensure your processes align with both global regulations and local market expectations.

The European Union Medical Device Regulation (EU MDR 2017/745) introduces stringent provisions to ensure the safety, effectiveness, and compliance of reprocessed medical devices. Below is an overview of the key requirements:

  • Reprocessing involves the cleaning, disinfection, sterilization, and preparation of a used medical device for safe reuse. Under MDR, reprocessing of single-use devices is particularly regulated and subject to strict control measures to maintain patient safety.
  • Reprocessing of single-use devices is only permissible in EU Member States where national laws explicitly allow this practice. Each country retains the authority to set stricter rules or even prohibit reprocessing entirely.
  • The European Commission has developed Common Specifications (CS) to guide reprocessing practices. These include Validation of cleaning, disinfection, and sterilization processes, and demonstration that the reprocessed device performs equivalently to the original.
  • Reprocessed devices must be clearly labeled to indicate they have undergone reprocessing. The labeling must distinguish between the reprocessor and the original manufacturer. Additionally, comprehensive IFUs must outline validated reprocessing steps and precautions.
  • Health institutions reprocessing single-use devices for in-house use may receive certain exemptions under national regulations. However, these institutions must still adhere to stringent safety and performance standards as defined in the MDR.
  • Reprocessors are required to establish mechanisms for tracking reprocessed devices and monitoring their performance post-market. Any adverse events or deviations must be reported promptly to relevant authorities.
  • Comprehensive risk management is essential for reprocessed devices. Reprocessors must evaluate the risks associated with:
    – Material degradation.
    – Functional changes due to repeated reprocessing.
    – Potential contamination or insufficient sterilization.

The MDR imposes rigorous controls on the reprocessing of medical devices, especially single-use devices, to uphold patient safety and device reliability. Entities involved in reprocessing must maintain compliance through diligent adherence to regulatory standards, robust validation processes, and transparent labeling practices.